EM500 Open-Loop Vector Control Inverter User Manual 123 ACR-P1 F14.49 Excitation Current Integral Time Constant ACR-T1 0.00 - 600.00 0.00: No Integral ms 10.00 ● F14.50 Torque Current Proportional Gain ACR-P2 0.00 – 100.00 0.50 ● F14.51 Torque Current Integral Time Constant ACR-T2 0.00 - 600.00 0.00: No Integral ms 10.00 ● F14.52 Position Loop Gain 0.000 - 40.000 1.000 ● F14.53 SVC Control Mode at Zero Frequency 0: Brake 1: Normal 2:
No output 2 〇 F14.54 SVC Zero Frequency Band-Type Brake Current 50.0 - 400.0 (100.0=Idling Current) % 100.0 〇 F14.55 SVC Low Frequency Excitation Current 50.0 - 150.0 (100.0=Idling Current) % 100.0 〇 F14.56 Voltage Feedforward Gain 0 - 100 % 0 ● F14.57 Field Weakening Control Options of Synchronous Motor 0: Disabled 1: Direct Calculation 2:
Automatic Adjustment 1 〇 F14.58 Field Weakening Factor of Synchronous Motor 100.00 - 200.00 % 100.00 ● F14.59 Maximum Field Weakening Current of Synchronous Motor 0.0 - 150.0 (100.0= Motor Rated Current) % 50.0 ● F14.60 Proportional Gain of Field Weakening Regulator of Synchronous Motor 0.00 - 10.00 0.50 ● F14.61 Integral Time of Field Weakening Regulator of 0.00 - 300.00 ms 10.00 ●