sinee — 6.2 Function Parameter Table

EM500 Open-Loop Vector Control Inverter User Manual 142 a F26.28 T6 Start time T5~23.59 0.00 〇 F26.29 Pressure at time T6 F25.03~F25.02 % /MP a 0.1 〇 F27 Winding rolling application F27.00 The application of macro 0: Winding mode 1:Unwinding mode 2:Wire drawing mode 3:Straight wire drawing machine mode 0 〇 F27.01 Feedforward Gain Effect channel 0: Feedforward Gain *Given source B 1: Feedforward Gain *Given source A 2: Feedforward Gain *10V 1 〇 F27.02 Feedforward Gain input mode 0:Feedforward gain invariability 1: 0.00~Upper Limit feedforward gain 2:- Upper Limit feedforward gain~+ Upper Limit feedforward gain 1 〇 F27.03 Feedforward Control Ones Place:Feedforward reset option 0:

Automatic reset 1: Terminal reset Tens Place:Feedforward power off and parking choice 0: Power off saved 1:

Power off unsaved 10 〇 F27.04 Upper Limit feedforward gain 0.00~500.00 % 500.00 〇 F27.05 Feedforward initial gain 0.00~500.00 % 50.00 ● F27.06 feedforward gain filtering time 0~1000 ms 0 ● F27.07 Feedforward range 0 0.00~ Feedforward range1 % 4.00 ● F27.08 Feedforward range 1 Feedforward range 1~ Feedforward range 2 % 12.00 ● F27.09 Feedforward range 2 Feedforward range 2~ Feedforward range 3 % 23.00 ● F27.10 Feedforward range 3 Feedforward range 3~ Feedforward range 4 % 37.00 ● F27.11 Feedforward range 4 Feedforward range 4~ Feedforward range 5 % 52.00 ● F27.12 Feedforward range 5 Feedforward range 5~100.00 % 72.00 ●