EM500 Open-Loop Vector Control Inverter User Manual F00.17=0: Set through F00.18 Upper limit frequency is set through F00.18. F00.17=1: AI1 F00.17=2: AI2 F00.17=3: AI3 F00.17=4: AI4 (Expansion Card) Upper limit frequency is set through "AI (percentage) * F00.18". F00.17=5: High-Frequency Pulse Input (X7) Upper limit frequency is set through "HDI (percentage) * F00.18". Please refer to the description of F00.04 for detailed explanations of AI1-AI4 and X7. F00.04 has the same meanings as AI1-AI4 and X7. 100.00% is the percentage inputted through F00.18 (Upper Limit Frequency). F00.17=6 or 7:
Communication Setting For master-slave communication (F10.05=1) and the inverter is slave (F10.06=0) upper limit frequency is set as “700FH (Main Frequency Setting by Communication) * F00.18 (upper limit frequency)* F10.08 (Receiving Proportionality Factor of Slave)”. 166 No. Function Range Unit Default Type F00.17 Upper Limit Frequency Control Options 0: Set through F00.18 1: AI1 2: AI2 3: AI3 4: AI4 (Expansion Card) 5: High-Frequency Pulse Input (X7) 6: Communication Percentage Setting 7:
Direct Upper Limit Frequency Communication Setting 0 F00.18 Upper Limit Frequency Lower Limit Frequency F00.19 - Maximum Frequency F00.16 Hz 50.00 ● F00.19 Lower Limit Frequency 0.00 - Upper Limit Frequency F00.18 Hz 0.00 ●