EM500 Open-Loop Vector Control Inverter User Manual 395 Conditio 02H JOG Running n 03H Autotuning Status 7200H 04H Slave Stop - 05H JJOG Stop 73FFH 06H Fault Status 07H Factory Inspection 08H - 0FFH Not Used Bit15 - 8 Fault Information 00H Inverter runs normally xxH Fault status of inverter, “xx” is the fault code 7201H Status word 2 Bit0 Set Direction 1 - Valid Setting 0 +Valid Setting Bit1 Running Direction 1 Frequency Output, Reverse 0 Frequency Output, Forward Bit3 - 2 Control Mode 00 Speed Control Mode 01 Torque Control Mode 10 Not used 11 Not used Bit4 Parameter Protection 1 Enabled 0 Disabled Bit6 - 5 Not Used Bit8 - 7 Set Mode 00 Keypad Control 01 Terminal Control 10 Communication Control 11 Not used Bit9 Not used Bit10 warning 0 No Warning 1 Warning Status (See 7230H) Bit15 - 11 Not used 7202H Monitoring frequency +/- status word 1 (1:
-; 0: +) Bit0 Output Frequency Bit1 Input Frequency Bit2 Synchronous frequency Bit3 Not Used Bit4 Estimated Feedback Frequency Bit5 Estimated Slip Frequency