EM500 Open-Loop Vector Control Inverter User Manual Elevation Back Elevation 1. DIP Switch 1 2. DIP Switch 2 3. Analog Signal Interface 4. Numeric Signal Interface 5. Screw Location Hole 6. Inverter Interface I.3 Expansion Terminal Function Table 1 IO Expansion Card Terminal Function 428 Type Item Terminal Description Auxiliary Power Supply Provide a working power supply for 24V-COM +24V Power Supply numeric input and output terminals Default setting: Connecting to 24V power supply Common Multi-function When driving the numeric input terminal PLC Input Terminal with external power supply, disconnect it from 24V terminal and connect it to external power supply.
Numeric Input X8 Multi-function Input Terminal 8 Optocoupler isolation, compatible with bipolar input of NPN and PNP Input impedance: 4.5 kΩ Input voltage range: 9 – 30 V See Table 3-17 X9 Multi-function Input Terminal 9 X10 Multi-function Input Terminal 10 X11 Multi-function Input Terminal 11 Multi-Fun ction Output Y3-COM OC Output Terminal Optocoupler isolation, OC output Maximum output voltage: DC48V Output current: 50 mA Analog AI4-GND Analog Input Terminal 4 Input range: DC -10V - +10V; the voltage