EM500 Open-Loop Vector Control Inverter User Manual Appendix II Multi-Functional IO Expansion Card 3 (EC-IO-A3) II.1 General EC-IO-A3 card is used for EM500 control terminal expansion, including the following resources: II.2 Installation Instructions Install IO expansion card 3 into the expansion slot EC-B (make sure that it is installed and buckled properly). Disassemble or install IO expansion card 3 only after inverter is powered off.
Figure 2 Installation of IO Expansion Card 3 430 Item Specification Description Input 1 temperature input Support PT100, KTY84-130/150 and PTC130/150 temperature sensor Output 1 relay output (NO) Y3:EA3-EC3, maximum output current of OC is 50mA; relay contactor capacity: 250VAC/3A or 30VDC/1A Power Supply +15V +15V-GND, max. output current is 100mA