sinee — 6.2 Function Parameter Table

EM600 High-Performance Vector Control Inverter User Manual 112 Function Name of Function Parameter Description Unit Default Property Code Code F18.41 - F18.42 Not Used - - - - F18.43 Zero Servo Position Offset 0 - 65535 0 × F18.44 - F18.50 Not Used - - - - F18.51 PID Output -300.0 - 300.0 % × F18.52 Spindle Orientation Setting Position 0 - 65535 0 × F18.53 Spindle Orientation Current Position 0 - 65535 0 × F18.54 Feed Setting High Byte 0 - 65535 0 × F18.55 Feed Setting Low Byte 0 - 9999 0 × F18.56 Feed Current High Byte 0 - 65535 0 × F18.57 Feed Current Low Byte 0 - 9999 0 × F18.58 Feedback Pulse High Byte 0 - 65535 0 × F18.59 Feedback Pulse Low Byte 0 - 65535 0 × F18.60 Not Used - - - - F19 Fault Record Group F19.00 Last fault type 0:

No Fault SC: Output Short Circuit Protection HOC: Instantaneous Overcurrent HOU: Instantaneous Overvoltage SOC: Stable Overcurrent SOU: Stable Overvoltage SIU: Stable Undervoltage IlP: Input Phase Loss OlP: Output Phase Lose Ol: Inverter Overload OH: Inverter Overheating Protection E11: Parameter Setting Conflict E12: Motor Overheating E13: Motor Overload E14: External Fault E15: Inverter EEPROM Fault 0 ×