sinee — II.2 Installation Instructions

EM600 High-Performance Vector Control Inverter User Manual Appendix II General Encoder Expansion Card (PG Card) II.1 General User shall purchase appropriate PG card from SINEE when using closed loop vector control.  Configuration: EM600 inverter is equipped with multiple general PG cards. User shall select PG card based on encoder output form. Models of PG cards are listed in the table below: II.2 Installation Instructions  Install PG card into expansion slot EC-A (make sure it is installed and buckled properly).  Disassemble or install PG card only after inverter is powered off. PG卡 Figure 2 Installation of PG Card 278 Model No.

Description Encoder interface EC-PG-O1 open collector output encoder complementary push-pull output encoders encoder with voltage output 6PIN connection terminal EC-PG-O2 open collector output encoder complementary push-pull output encoders encoder with voltage output With frequency dividing output and PG output is open collector. Input: 6PIN connection terminal Output: 4PIN connection terminal EC-PG-D1 Differential output encoder (long line drive encoder) Wire-saved UVW differential output encoder 9PIN connection terminal EC-PG-D3 Differential output encoder (long line drive encoder) Wire-saved UVW differential output encoder With frequency dividing output and PG output is open collector.

Input: 9PIN connection terminal Output: 4PIN connection terminal EC-PG-U1 UVW differential output encoder DB15 female connector EC-PG-R1 Rotary transformer output encoder DB9 female connector