sinee — 3.2.6.1 Inverter and Motor Connection

EM600 High-Performance Vector Control Inverter User Manual 3.2.5.7 Noise Filter Installation at Power Supply Side Noise filter can suppresss the noise transmitted between power cable and inverter and impacts of the noise generated by inverter on the power grid.  Special noise filter is required for inverter; general noise filter is not adopted for effect purpose.  Correct and incorrect installation methods of noise filter (Figure 3–6 and Figure 3–7).

MCCB IM EMC 其它控 制设备 Other Control Device Figure 3–6 Correct Installation of Noise Filter MCCB IM 其它控 制设备 Other Control Device (a) MCCB EM600 变频器 EM600 Inverter IM (b) Figure 3-7 Incorrect Installation of Noise Filter 3.2.6 Wiring of Main Circuit on Output Side 3.2.6.1 Inverter and Motor Connection Connect output terminals U, V and W of inverter to input terminals U, V and W of motor. Confirm whether motor runs forward after receiving a forward running command. If not, please switch any two connection cable of output terminals U, V and W of inverter.

33 Special Noise Filter EEMM660000 变Inve频rte器r Ge普ner通al N噪ois声e 滤Filt波er器 EEMM66000 0 In变ver频ter器 General No滤ise 波Filt器er 其Ot它her 控 Control 制Dev设ice备