sinee — 6.2 Function Parameter Table

EM600 High-Performance Vector Control Inverter User Manual 6.2 Function Parameter Table 57 A Ampere mH Millihenry h Hour Revolutions per minute Degree Celsius Meter rpm ℃ m ★ %: Its benchmarks are different depending upon different physical quantities; kWh: kilowatt-hour. Factory defaults of function codes or reset to the defaults (F12.14=1). In figures (for For various power segments, present values of function codes are the default values. example 50.00) Default For different power segments, function codes have different defaults. Model For different power segments or batches, function codes have different defaults.

XXX Property change of function codes (whether change is permitted and applications for change) Can be changed while inverter is running; present function code can be changed regardless of status of inverter. ● Property Can not be changed while inverter is running; present function code can be changed except running status. 〇 Read only: property of present function code can not be changed under any status. × Function Name of Function Parameter Description Unit Default Property Code Code F00 Basic Function Parameter Group F00.00 Not Used F00.01 Drive Control Mode of Motor 1 0: V/F control (VVF) 1: Sensorless Vector Control (SVC) 2.

Feedback Vector Control (FVC) 0 〇 F00.02 Command Source Options 0: Keypad Control (LOC/REM indicator on) 1: Terminal Control (LOC/REM indicator off) 2: Communication Control (LOC/REM indicator flickers) 0 〇 F00.03 Terminal Control Mode Options 0: Terminal RUN for running, Forward/Reverse (F/R) 1: Terminal RUN for forward, F/R reverse 2: Terminal RUN for forward, Xi stop, F/R reverse 3: Terminal RUN for running, Xi stop Forward/Reverse (F/R) 0 〇 F00.04 Main Frequency 0: Numeric frequency setting 0 〇