EM600 High-Performance Vector Control Inverter User Manual 65 Function Name of Function Parameter Description Unit Default Property Code Code to AI2 54: Switch Main Frequency Source to AI3 55: Switch Main Frequency Source to High-Frequency Pulse Input 56: Switch Main Frequency Source to Communication Setting 57: Inverter Enabled 58~68 Not Used 69: Reverse Forbidden 70~124: Not Used 125: Spindle Orientation Enable 126: Spindle Orientation Position 0 127: Spindle Orientation Position 1 128: Spindle Orientation Position 2 129: Transmission Gear 0 130: Transmission Gear 1 131: Spindle clamp interlock signal 132: Feed Control Enabled 133: Homing Enabled 134: Feed selection bit 0 135:
Feed selection bit 1 136: Feed selection bit 2 137: Original Point input signal 138: Forward Feed 139: Reverse Feed 140: Feed Stepping Increase 141: Feed Stepping Decrease F02.15 Positive/Negative Logic 1 of Numeric Input Terminal D7 D6 D5 D4 D3 D2 D1 D0 *00 00000 〇 * X7 X6 X5 X4 X3 X2 X1 0: Positive Logic, Enabled at On/Disabled at Off 1: Negative Logic, Disabled at On/Enabled at Off F02.16 Positive/Negative Logic 2 of Numeric Input Terminal D7 D6 D5 D4 D3 D2 D1 D0 000 00000 〇 X1 1 X10 X9 X8 AI 4 AI3 AI 2 AI1 0: Positive Logic, Enabled at On/Disabled at Off 1:
Negative Logic, Disabled at On/Enabled at Off F02.17 Filter Times of Numeric Input Terminal 0-100, 0 for No Filter, n for sampling once every n ms 2 〇