sinee — 6.2 Function Parameter Table

EM600 High-Performance Vector Control Inverter User Manual 83 Function Name of Function Parameter Description Unit Default Property Code Code Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 F08.32 Running Time of Preset Speed 7 0.0 - 6000.0 s /min 5.0 ● F08.33 Setting of Preset Speed 8 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3:

Acceleration/Deceleration Time 4 0 ● F08.34 Running Time of Preset Speed 8 0.0 - 6000.0 s /min 5.0 ● F08.35 Setting of Preset Speed 9 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 0 ● F08.36 Running Time of Preset Speed 9 0.0 - 6000.0 s /min 5.0 ● F08.37 Setting of Preset Speed 10 Ones Place: Running Direction 0: Forward 0 ●