sinee — 6.2 Function Parameter Table

EM600 High-Performance Vector Control Inverter User Manual 95 Function Name of Function Parameter Description Unit Default Property Code Code F12.10 UP/DOWN Acceleration/Deceler ation Rate 0.00: Automatic Rate 0.01 - 500.00 Hz/s 5.00 〇 F12.11 UP/DOWN Offset Clear 0: Not to Clear 1: Clear at Non-Running Status 2: Clear at Disabled UP/DOWN 1 〇 F12.12 Power Failure Save of UP/DOWN Offset 0: Disabled 1: Enabled (only at modified offset) 0 〇 F12.13 Kilowatt-Hour Meter Clear 0: Not to Clear 1: Clear 0 ● F12.14 Reset 0: No Operation 1:

Reset (exclusive of motor parameter, inverter parameter, manufacturer parameter, running and power-on time record) 0 〇 F12.15 Accumulated Power-On Time h 0 - 65535 h XXX × F12.16 Accumulated Power-On Time min 0 - 59 min XXX × F12.17 Accumulated Running Time h 0 - 65535 h XXX × F12.18 Accumulated Running Time min 0 - 59 min XXX × F12.19 Modbus Data Format 0.40 - 650.00 kW Up To Specific Model × F12.20 Inverter Rated Power 60 - 690 V Up To Specific Model × F12.21 Inverter Rated Voltage 0.1 - 1500.0 A Up To Specific Model × F12.22 Performance Software Serial Number1 XXX.XX XXX.XX × F12.23 Performance Software Serial Number2 XX.XXX XX.XXX × F12.24 Function Software Serial Number 1 XXX.XX XXX.XX × F12.25 Function Software Serial Number 2 XX.XXX XX.XXX × F12.26 Keypad Software Serial Number 1 XXX.XX XXX.XX ×