EM600 High-Performance Vector Control Inverter User Manual 97 Function Name of Function Parameter Description Unit Default Property Code Code Control 1: Torque Control F13.01 Torque Setting 0: Numeric Torque Setting F13.02 1: AI1 2: AI2 3: AI3 4: AI4 (Expansion Card) 5: High-Frequency Pulse Input (X7) 6:
Communication Setting (Full ranges of options 1 to 6, correspond to numeric torque setting F13.02) 0 〇 F13.02 Numeric Torque Setting -200.0 - 200.0 (100.0= Motor Rated Torque) % 100.0 ● F13.03 Preset Torque 1 -200.0 - 200.0 % 0.0 ● F13.04 Preset Torque 2 -200.0 - 200.0 % 0.0 ● F13.05 Preset Torque 3 -200.0 - 200.0 % 0.0 ● F13.06 Torque Control Acceleration/Deceler ation Time 0.00 - 120.00 s 0.05 ● F13.07 Not Used F13.08 Upper Limit Frequency of Torque Control 0: Set through F13.09 1: AI1 2: AI2 3: AI3 4: AI4 (Expansion Card) 5: High-Frequency Pulse Input (X7) 6: Communication Percentage Setting 7:
Communication Direct Setting 0 〇 F13.09 Upper Limit Frequency of Torque Control 0.00 - Maximum Frequency F00.16 Hz 50.00 ● F13.10 Upper Limit Frequency Offset 0.00 - Maximum Frequency F00.16 Hz 0.00 ● F13.11 Static Friction Torque Compensation 0.0 - 100.0 % 0.0 ● F13.12 Static Friction Compensation Frequency Range 0.00 - 50.00 Hz 1.00 ● F13.13 Not Used - - - -