EM630/TC6A Closed-Loop Vector Hoist Inverter User Manual 12 Items Specifications Brake frequency: 0.01 - Maximum frequency, brake DC Brake time: 0 - 30S Brake current: 0% - 100% rated current Signal Input Source Communication and preset speed Reference Power Supply 10 V/20 mA Terminal Control Power 24 V/200 mA Supply Numeric Input Terminal 7 numeric multi-functional input terminals 3 analog inputs: Analog Input Terminal 1 voltage input (0 - 10V); Function 2 voltage inputs (0 - 10V) or current inputs (0 - 20mA) of Input 2 OC multi-functional outputs and 2 relay and multi-functional outputs. Output Maximum output current of OC: 50mA; relay contact Numeric Output Terminal capacity:
250VAC/3A or 30VDC/1A. When the relay works, EA-EC and RA-RC is on, but EB-EC and RB-RC is off. 2 multi-functional analog output terminals are with Analog Output Terminal the output 0 - 10V or 0 - 20mA. LED LED displays relevant information about the inverter. Keypad Upload and download the parameter setting Display Parameter Copy information of the inverter to realize rapid copy. Short circuit, overcurrent, overload, overvoltage, Protection Protection undervoltage, phase loss, overheating, overspeed, abnormal braker, external fault, etc. To be installed indoor with an altitude less than Installation Site 1,000 meters, free from dust, corrosive gas and direct sunlight.
Working Ambient Temperature -10˚C - +40˚C, 20% - 90%RH (no condensation) Condition Vibration Storage Temperature -25˚C - +65˚C Wall mounting, floor mounting (electrical cabinet) Installation Method and flush mounting Protection Degree IP20 Cooling Method Forced air cooling