EM630/TC6A Closed-Loop Vector Hoist Inverter User Manual V M1 I V M2 I V AI2 I V AI3 I OFF 485 ON S2 S3 S4 S5 S1 PE X2 X3 X4 X6 X7 EA EB EC X1 X5 AI1 AI2 AI3 10V RS485 24V M1 RJ45 M2 GND A+ A- PLC COM Y1 Y2 COM GND RJ45 RA RB RC Note: The jump wires J9 and J10 of the terminal block are equipped by the manufacturer. No user is allowed to change them, or else the inverter may not work normally. Figure 3–12 Control Circuit Terminal Block 3.3.2 Function and Wiring of Control Circuit Terminals See Table 3–5 for the functions of control circuit terminals. Table 3–5 Control Circuit Terminal Functions 40 Terminal Mode Terminal Terminal Function No.
+10V Power Supply Offers a +10V power supply, maximum 10V-GND output current: 20mA. Offers a +24V power supply, generally used as a working power supply for +24V Power Supply 24V-COM numeric input or output terminal, or external device power supply. Auxiliary Maximum output current: 200mA Power Supply Default setting: connecting to a 24V power supply Multi-function Input Common Terminal When driving the numeric input terminal PLC with an external power supply, disconnect it from a 24V and connect it to the external power supply. Analog Input Terminal 1 Input voltage range: DC 0 - 10V AI1-GND Analog Output Input impedance: 1MΩ AI2-GND Analog Input Input range: DC 0 - 10V/0 - 20mA;