sinee — Em630:tc6a EM630

EM630/TC6A Closed-Loop Vector Hoist Inverter User Manual Braking Resistor MCCB 3- Phase Power Supply MC R/L1 PB U V M S/L2 EM630 W Grounding 24V Output 200mA T/L3 Groundin g PLC 24V J7 Keypad Interface Multi-Function Input Terminal RUN X1 J3 PG Card Interface D1 F/R X2 X3 J4 Function Extension D3 D2 X5 X4 EA Card Interface D4 D5 X6 EC EB Relay Output Contact Above DC30V 10mA: below 3A Above AC250V 10mA:

below 3A COM X7 RA +10V/20mA 10V RC RB 1kO~ 5kO Frequency AI1 AI2 Y1 Setting Potentiometer AI3 Multi-Function OC Output GND A+ 0V~24V/0mA~50mA A - M1 V/I Multi- Function Grounding PE GND J9 M2 V/I Analog Voltage COM J10 GND PE Output V M1 I V M2 I V AI2 I V AI3 I OFF 485 ON S2 S3 S4 S5 S1 Figure 3–21 Standard Wiring of Control Circuit 3.4 Extending Keypad Wire 1) External keypad interface adopts RJ45 interface and the extending wire is general network cable (connection plug executes the standard EIA/TIA568B). 2) Wiring is shown in Figure 3–22. This wiring mode will facilitate your installation and debugging greatly. 48 0-10V 0-10V/0-20mA 0-10V/0-20mA 3 2 1 COM