sinee — 9.2 Table of functional parameters

User Guide of EM730 Series Inverter 4.4 Operation Monitoring 4.4.1 Normal monitoring In the monitoring status mode 1 of EM730, you can set any function code to be viewed between F12.33 and F12.37. When F12.32=1, the monitoring mode 1 will be enabled. If the Level 0 monitoring menu appears, you can press the right shift key to switch the monitoring parameters according to the order set for each function code between F12.33 and F12.37. When the inverter changes from the stop status to running status, the monitoring parameter will automatically change from the current value to that indicated by F12.33.

When the inverter changes from the running status to stop status, the monitoring parameter will automatically change from the current value to that indicated by F12.34. 4.4.2 Editing Mode Quick change in the monitoring mode: When F00.04 is set to “0: digital frequency setting F00.07”, turn the potentiometer key to directly change the offset; When F00.04 is set to “8: digital potentiometer”, turn the potentiometer key to change the set frequency of F12.42 digital potentiometer. In this case, turn the potentiometer key to enter the editing mode. The value will change from the second digit of the digital tube by default. The digital tube corresponding to the changed digit will flash.

Press the right shift key to move to next digit on the right. Press the ESC key original value. Or, press the ENTER key to confirm the change and exit the editing mode. The indicator will not be flicker. Press the right shift key to cancel change and return to the to enable the normal monitoring mode: switch to next monitoring parameter. Fig. 4-6 shows the editing status in the monitoring mode. 36