sinee — 9.2 Table of functional parameters

User Guide of EM730 Series Inverter (b) Wiring diagram of three-line control (F00.03=3) (d) Forward/reverse running logic (F04.19=0, F00.03=3) Fig. 5-3 Three-line Control The three-line control logic of the EM730 series inverter is consistent with the conventional electrical control. The keys and knob switches should be used correctly as shown in the schematic diagram. Otherwise, operation errors may be caused. 5.6 Common Process Parameters of Inverter Note: Common process parameters may also include the input and output terminal function 43 Function Default Function code name Parameter description Unit Attribute code setting F00.01 Drive control mode of motor 1 0: V/F control (VVF) 1:

Speed sensorless vector control (SVC) 0 〇 F00.04 Options of main frequency source A 0: digital frequency setting F00.07 1:AI1 2:AI2 5: high frequency pulse input (X5) 6: Percentage setting of main frequency communication 7: Direct setting of main frequency communication 8:

digital potentiometer setting 0 〇 F00.07 Digital frequency setting 0.00 to maximum frequency F00.16 Hz 0.00 ● F00.14 Acceleration time 1 0.00~650.00(F15.13=0) s 15.00 ● F00.15 Deceleration time 1 0.00~650.00(F15.13=0) s 15.00 ● F00.16 Maximum frequency 1.00~600.00 Hz 50.00 〇 F00.18 Upper frequency limit Lower frequency limit F00.19 to maximum frequency F00.16 Hz 50.00 ● F00.19 Lower frequency limit 0.00 to upper frequency limit F00.18 Hz 0.00 ● F00.21 Reverse control 0: Allow forward/reverse running 1: Prohibit reversing 0 〇