sinee — 9.2 Table of functional parameters

User Guide of EM730 Series Inverter 88 F09.02 PID feedback source 1: AI1 2: AI2 3: Reserved 4: retention 5: PULSE, high-frequency pulse (X5) 6: Communication setting 1 〇 F09.03 PID setting feedback range 0.1 - 6000.0 100.0 ● F09.04 PID positive and negative action selection 0: positive 1: negative 0 〇 F09.05 Proportional gain 1 0.00-100.00 0.40 ● F09.06 Integral time 1 0.000 - 30.000, 0.000: no integral s 2.000 ● F09.07 Differential time 1 0.000-30.000 ms 0.000 ● F09.08 Proportional gain 2 0.00-100.00 0.40 ● F09.09 Integral time 2 0.000 - 30.000, 0.000: no integral s 2.000 ● F09.10 Differential time 2 0.000-30.000 ms 0.000 ● F09.11 PID parameter switching conditions 0: no switching 1:

switching via digital input terminal 2: automatic switching according to deviation 3: Automatic switching by frequency 0 ● F09.12 PID parameter switching deviation 1 0.00 - F09.13 % 20.00 ● F09.13 PID parameter switching deviation 2 F09.12 - 100.00 % 80.00 ● F09.14 Initial PID value 0.00-100.00 % 0.00 ● F09.15 PID initial value holding time 0.00~650.00 s 0.00 ● F09.16 Upper limit of PID output F9.17~+100.0 % 100.0 ● F09.17 Lower limit of PID output –100.0~F9.16 % 0.0 ● F09.18 PID deviation 0.00-100.00 (0.00: invalid) % 0.00 ●