User Manual of EM730/EM730E Series Inverter F00.17=0: set by F00.18 The upper frequency limit is set by F00.18. F00.17=1:AI1 F00.17=2:AI2 The upper frequency limit depends on AI (percentage) * F00.18. For the details of AI1 and AI2, refer to the F00.04 description. They have the same meaning. 100.00% is the percentage relative to the set value of F00.18 (upper frequency limit). F00.17=5: High-frequency pulse input (X5) The upper frequency limit depends on HDI (percentage) * F00.18. For the details of AI1-AI2 and X5, refer to the F00.04 description. They have the same meaning. 100.00% is the percentage relative to F00.18 (maximum frequency). F00.17=6 or 7:

communication setting The torque depends on the communication and the like.  If the master-slave communication (F10.05=1) is enabled, and the inverter works as the slave (F10.06=0), the actual upper frequency limit is “700FH (master-slave communication setting) * F10.08 (slave receiving proportional coefficient) * F00.18 (upper frequency limit)”, and the 700FH data range is -100.00% to 100.00%, as detailed in Table 12-31.  For general communication (F10.05=0): a. F00.17=6 , the actual frequency limit is “700AH (communication setting of the upper frequency limit) * F00.18 (upper frequency limit)”. b.

F00.17=7, the actual frequency limit is “7017H (communication setting of the upper frequency limit)”. The 700AH data range is 0.00% to 200.00%, and the 7017H data range is 0.00 to F00.16 (maximum frequency). For details, see Table 12-31 . ranging from Fdown to Fmax; F00.18 is the highest frequency allowed after the inverter is started. It is represented by Fup, F00.19 is the lowest frequency allowed after the inverter is started. It is represented by Fdown, ranging from 0.00Hz to Fup. 142 F00.19 Lower frequency limit 0.00 to upper frequency limit F00.18 Hz 0.00 ●