User Manual of EM730/EM730E Series Inverter 156 “E14” and freely stop running. 24 Switching of RUN command to keyboard The current command channel depends on the status of these two terminals and setting of F00.02. The priority is as follows: “24: switching of RUN command to keyboard” > “25: switching of RUN command to communication” > “F00.02: command source option”. Refer to the F00.02 description for details. 25 Switching of RUN command to communication 26 Frequency source switching This terminal is mainly used to switch the frequency sources in conjunction with the function code F00.06. When F00.06=3 to 5, this terminal will be valid. Refer to the F00.06 description.
27 Clearing of regular running time The regular running function is defined by F16.05. This terminal can be used to clear the running time (reset the remaining time of regular running). Refer to the F16.05 description. 28 Speed control/torque control switching These two terminals are used to change the current inverter control mode in conjunction with F13:00 When #28 terminal is valid, speed control and torque control can be switched; and when #29 terminal is valid, only speed control is enabled. See the F13.00 description. 29 Torque control prohibition 30 Motor 1/Motor 2 switching This terminal is used to determine the current valid motor in conjunction with F00.28.
If #30 terminal is valid, the motors will be switched based on the F00.28 setting. See the F00.28 description. 31 Resetting of simple PLC status (running from the first segment, with the running time cleared) When this terminal is valid, the simple PLC module will restart running from the first segment. To further understand this function, you can view the simple PLC description of the F08 group. 32 simple PLC time pause (keep running at current segment) When this terminal is valid, the simple PLC module will keep running at the current segment. When this terminal is invalid, the simple PLC module will continue to run after running at the current segment.
33 Reserved 34 counter input (≤250Hz) It is a pulse input terminal that has the counting function. The input pulse frequency is limited to 250Hz or below, and only one terminal can be set with this function. See the description of the function codes F16.03 to F16.04. 35 High-speed count input (≤100kHz, only valid for X5) It is a pulse input terminal that has the counting function. The input pulse frequency is limited to 100kHz or below. This is valid only for the terminal X5 (that is, only F02.06=35 can be set). See the description of the function codes F16.03 to F16.04. 36 Count clearing This terminal is used to clear the counter that has a counting