User Manual of EM730/EM730E Series Inverter corresponding output can be shielded by setting the corresponding bit of this function code to 1. It is usually not necessary for DO to output certain statuses during jog running. The If F03.08=xxx1x is set and the FAR output is valid, the actually selected output terminal will not output the active level. This function code is subject to bit operation. For specific settings, refer to the description of the function code F02.15. Table 7-7 173 Function code Function code Default Parameter description Unit Attribute name setting F03.08 Output status control in jog D7 D6 D5 D4 D3 D2 D1 D0 00000 〇 * * * REV FDT 2 FDT 1 FAR RUN 0: valid in jogging 1:

invalid in jogging Function Default setting Function code name Parameter description Unit Attribute code F03.09 Y1 valid delay time 0.000-30.000 s 0.000 ● F03.10 Y1 invalid delay time 0.000-30.000 s 0.000 ● F03.13 R1 valid delay time 0.000-30.000 s 0.000 ● F03.14 R1 invalid delay time 0.000-30.000 s 0.000 ●