User Manual of EM730/EM730E Series Inverter You can set this parameter to 1 to restore the default settings of all parameters, except the motor parameters (F01 group), inverter parameters, manufacturer parameters, power-on time (F12.15/16) and operating time (F12.17, 18). ★ This operation is irreversible. Please set it carefully. F12.15 and F12.16 are used together to check the cumulative power-on time of the inverter from delivery to the current moment (you only need to power on the inverter). The cumulative power-on time is accurate to one minute and nearly 65536 hours (about 7.5 years) at most.
If F12.15=50 and F12.16=33, it means that the current inverter has been powered on for 2 days, 2 hours and 33 minutes. ★ This parameter can be viewed only and cannot be changed or cleared. F12.17 and F12.18 are used together to check the cumulative operating time of the inverter from delivery to the current moment (the inverter should be in the running status). The cumulative power-on time is accurate to one minute and nearly 65536 hours (about 7.5 years) at most. If F12.17=47 and F12.18=39, it means that the current inverter has been running for 1 day, 23 hours and 39 minutes. ★ This parameter can be viewed only and cannot be changed or cleared.
242 Function Function Default setting Parameter description Unit Attribute code code name F12.14 Restoration of default setting 0: No operation 1: restoration of factory defaults (excluding the motor parameters, inverter parameters, manufacturer parameters, running and power-on time record) 0 〇 Function Default Function code name Parameter description Unit Attribute code setting F12.15 Cumulative power-on time (h) 0 - 65535 h 0 × F12.16 Cumulative power-on time (min) 0 - 59 min 0 × Function Default Function code name Parameter description Unit Attribute code setting F12.17 Cumulative running time (h) 0 - 65535 h 0 × F12.18 Cumulative running time (min) 0 - 59 min 0 ×