User Manual of EM730/EM730E Series Inverter F12.32=0 : monitoring mode 0. The LED switching display and LCD small-line (7-line) display are dependent on the settings of the function codes F12.04 to F12.08. For the selected function codes, please refer to their parameter description. F12.32=1 : monitoring mode 1. The LED switching display and LCD small-line (7-line) display are dependent on the settings of the function codes F12.33 to F12.37. You can select any function code. F12.33=18.00 means that the function code F18.00 is displayed. The UP/DOWN function is valid. When F12.41=0, the UP/DOWN function can reduce the output frequency of the inverter to 0 without reversing.
When F12.41=1, the UP/DOWN function can reduce the output frequency of the inverter to 0, followed by reverse running of the motor. For the digital potentiometer setting, see the setting of the main frequency source A. 244 3 of Mode 1 (LED stop status display parameter 2) F12.36 Running status display parameter 4 of Mode 1 (LED stop status display parameter 3) 0.00 - 99.99 18.08 ● F12.37 Running status display parameter 5 of Mode 1 (LED stop status display parameter 4) 0.00 - 99.99 18.09 ● Function Default Function code name Parameter description Unit Attribute code setting F12.41 Options of UP/DOWN zero crossing 0: prohibit zero crossing 1:
allow zero crossing 0 〇 Function Default Function code name Parameter description Unit Attribute code setting F12.42 Frequency setting of digital potentiometer 0.00 to maximum frequency F00.16 Hz 0.00 × F12.43 Digital potentiometer torque setting 0.00-|Digital torque setting F13.02| % 0.0 ×