User Manual of EM730/EM730E Series Inverter Response PDU Error PDU deceleration time 1 (F00.15) to 6.00: Below is an example of a request to set the acceleration time 1 (F00.14) to 5.00 and ★ This function code cannot be used to change the parameters of the attribute “○” (it cannot be changed during operation). That is, only the parameters of the attribute “●” (it can be changed during operation) can be changed. Otherwise, the error code 1 will be returned.
323 Function code 1 byte 0x42 Starting Address 2 bytes 0x0000 - 0xFFFF Number of 2 bytes 1 - 16 registers Error code 1 byte 0xC2 Exception code 1 byte See Table 4-33 Request Respond Domain name (0x) Domain name (0x) Domain name (0x) (normal) (abnormal) Function 42 Function 42 Function C2 Starting address Hi 00 Starting address 00 03 Hi Exception Starting address Lo 0E Starting address 0E code Lo Number (Hi) of registers 00 Number (Hi) of 00 registers Number (Lo) of registers 02 Number (Lo) of 02 registers Number of bytes 04 Register value Hi 01 (F00.14) Register value Lo F4 (F00.14) Register value Hi 02 (F00.15) Register value Lo 58 (F00.15)