sinee — EM730 User Manual

User Manual of EM730/EM730E Series Inverter 11.4.3 Response delay The response delay (depending on the function code F10.04) is defined as the time interval from the reception of valid data frame[7 ] (data in the RS-485 network, different from the command sent by the keyboard) to data parsing and return. Since the starting and ending characters are defined in the standard protocol, it is impossible to avoid response delay, at least “3.5-character time interval + 1 ms (chip stabilization time of 485 protocol, t wait2 )”. The specific minimum time interval is related to the baud rate. If the baud rate is 9600bps, the minimum response delay is 5ms (3.5Ч10/9600+1=4.64≈5).

If the communication data involves EEPROM operation, the time interval will be longer. [ 7 ]: Valid data frame: Sent by the external master station (not keyboard) to this machine. The function code, length and CRC of the data are correct.Fig . 4-23 shows the data sending segment (t send ), sending end segment (t wait1 ), 75176-to-sending wait segment (t wait2 ), data return segment (t return ), and 75176-to-receiving wait segment (t wait3 ). t t wait 2 t wait 3 t send t wait 1 t return Fig.

4-23 Timing Parse Diagram of Complete Data Frame 11.4.4 Communication timeout The communication time interval △ t is defined as the period from the previous reception of valid data frames by the slave station (inverter) to next reception of valid data frames. If △ t is greater than the set time (depending on the function code F10.03; this function is invalid if set to 0), it will be regarded communication timeout. 341