User Manual of EM730/EM730E Series Inverter parameter will automatically change from the current value to that indicated by F12.33. When the inverter changes from the running status to stop status, the monitoring parameter will automatically change from the current value to that indicated by F12.34. 4.4.2 Editing Mode Quick change in the monitoring mode: to directly change the offset; When F00.04 is set to “0: digital frequency setting F00.07”, turn the potentiometer key to change the set frequency of F12.42 digital potentiometer. In this case, turn the potentiometer key When F00.04 is set to “8: digital potentiometer”, turn the potentiometer key enter the editing mode.
The value will change from the second digit of the digital tube by default. The digital tube corresponding to the changed digit will flash. Press the right shift key to to move to next digit on the right. Press the ESC key to cancel change and return to the original value. Or, press the ENTER key to confirm the change and exit the editing mode. The indicator will not be flicker. Press the right shift key to enable the normal monitoring mode: switch to next monitoring parameter. Fig. 4-6 shows the editing status in the monitoring mode. Flicker bit Flicker bit Flicker bit Fig.
4-6 Editing Status in the Monitoring Mode Flicker bit 4.5 Run/Stop After setting the parameters, press the RUN key to enable the normal operation of 55