User Manual of EM730/EM730E Series Inverter 74 F02.41 Minimum input of curve 3 0.00V - F02.43 V 0.10 ● F02.42 Minimum input setting of curve 3 –100.0 - +100.0 % 0.0 ● F02.43 Input of inflection point 1 of curve 3 F02.41 - F02.45 V 2.50 ● F02.44 Input setting of inflection point 1 of curve 3 –100.0 - +100.0 % 25.0 ● F02.45 Input of inflection point 2 of curve 3 F02.43 - F02.47 V 7.50 ● F02.46 Input setting of inflection point 2 of curve 3 –100.0 - +100.0 % 75.0 ● F02.47 Maximum input of curve 3 F02.45 - 10.00 V 9.90 ● F02.48 Maximum input setting of curve 3 –100.0 - +100.0 % 100.0 ● F02.49 Minimum input of curve 4 -10.00 - F02.51 V -9.90 ● F02.50 Minimum input setting of curve 4 –100.0 - +100.0 % -100.0 ● F02.51 Input of inflection point 1 of curve 4 F02.49 - F02.53 V -5.00 ● F02.52 Input setting of inflection point 1 of curve 4 –100.0 - +100.0 % -50.0 ● F02.53 Input of inflection point 2 of curve 4 F02.51 - F02.55 V 5.00 ● F02.54 Input setting of inflection point 2 of curve 4 –100.0 - +100.0 % 50.0 ● F02.55 Maximum input of curve 4 F02.53 - 10.00 V 9.90 ● F02.56 Maximum input setting of curve 4 –100.0 - +100.0 % 100.0 ● F02.57 AI1 filtering time 0.00 - 10.00 s 0.10 ● F02.58 AI2 filtering time 0.00 - 10.00 s 0.10 ● F02.61 AD hysteresis code 2 - 50 2 ○ F02.62 Selection of analog input AI1 type 0:
0~10V 3: -10~10V 4: 0~5V 0 〇 F02.63 Selection of analog input AI2 type 0: 0~10V 1: 4~20mA 2: 0~20mA 4: 0~5V 0 F02.66 Selection of AI2 current input impedance 0: 500Ω 1: 250Ω 0 〇 F03 Output terminal function group F03.00 Options of Y1 output function 0: no output 1: inverter running (RUN) 2: up to output frequency (FAR) 3: output frequency detection FDT1 4: output frequency detection FDT2 5: reverse running (REV) 1 ○ F03.02 Options of R1 output function (EA-EB-EC) 7 ○