User Manual of EM730/EM730E Series Inverter 76 0: valid in jogging 1: invalid in jogging F03.09 Y1 valid delay time 0.000~30.000 s 0.000 ● F03.10 Y1 invalid delay time 0.000~30.000 s 0.000 ● F03.13 R1 valid delay time 0.000~30.000 s 0.000 ● F03.14 R1 invalid delay time 0.000~30.000 s 0.000 ● F03.17 Single pulse time of Y1 output 0.001~30.000 s 0.250 ● F03.19 Single pulse time of R1 output 0.001~30.000 s 0.250 ● F03.21 Options of analog output M1 0: running frequency (absolute value) 1: set frequency (absolute value) 2: output torque (absolute value) 3: set torque (absolute value) 4: output current 5: Output voltage 6: bus voltage 7: output power 8:AI1 9:AI2 12:

High-frequency pulse input (with 100% corresponding to 100.00kHz) 13: Communication setting 1 14: count value 15: length value 16: PID output 18: PID feedback 19: PID setting 30: Communication setting 2 0 〇 F03.27 M1 output bias -100.0~100.0 % 0.0 ● F03.28 M1 output gain -10.000~10.000 1.000 ● F03.31 Control logic options of PLC output terminal D7 D6 D5 D4 D3 D2 D1 D0 0*0 〇 * * * * * R1 * Y1 0: Output 1: no output