sinee — EM730 User Manual (EN)

User Manual of EM730/EM730E Series Inverter 81 F05.18 Flux compensatio n gain of synchronous motor 0.00~500.00 % 0.00 ● F05.19 Filtering time constant of flux compensatio n of synchronous motor 0.00 - 10.00 s 0.50 ● F05.20 Change rate of VF separate power supply setting -500.0~+500.0 % 0.0 ● F06 Vector control parameter group F06.00 Speed proportional gain ASR P1 _ 0.00-100.00 12.00 ● F06.01 Speed integral time constant ASR T1 _ 0.000-30.000 0.000: no integral s 0.200 ● F06.02 Speed proportional gain ASR P2 _ 0.00-100.00 8.00 ● F06.03 Speed integral time constant ASR T2 _ 0.000-30.000 0.000:

no integral s 0.300 ● F06.04 Switching frequency 1 0.00 to switching frequency 2 Hz 5.00 ● F06.05 Switching frequency 2 Switching frequency 1 to maximum frequency F00.16 Hz 10.00 ● F06.06 No-load current gain 50.0~300.0 % 100.0 ● F06.07 Filtering time constant of speed loop 0.000 - 0.100 s 0.001 ●