User Manual of EM730/EM730E Series Inverter 88 F07.09 Instantaneous stop/no-stop recovery voltage Instantaneous stop/no-stop operating voltage to 100.0 % 86.0 ● F07.10 Check time for instantaneous stop/no-stop recovery voltage 0.00-100.00 s 0.50 ● F07.11 Current limit control 0: Invalid 1: limit mode 1 2: limit mode 2 2 〇 F07.12 Current limit level 20.0-180.0(100.0 = the rated current of inverter) % 150.0 ● F07.13 Quick current limit options 0: Invalid 1: valid 0 〇 F07.14 Protection retries 0-20; 0: Disable protection retry 0 〇 F07.15 Options of digital output action in protection retries 0: no action 1:

action 0 〇 F07.16 Interval of protection retries 0.01 - 30.00 s 0.50 ● F07.17 Restoration time of protection retries 0.01 - 30.00 s 10.00 ● F07.18 Action option of protection E08 * E07 * E02 E06 E05 E04 0 *0 *0000 〇 0: allow protection retry 1: disable protection retry F07.19 Action option 1 of protection E21 E16 E15 E14 E13 * E08 E07 000 00*00 〇 0: free stop 1: stop according to stop mode F07.20 Action option 2 of protection E28 E27 * E23 00*0 〇 0: free stop 1: stop according to stop mode F07.21 Options of load loss 0: Invalid 1: valid 0 ●