sinee — EM760 User Manual

User’s Guide for EM760 series high-performance vector inverter 73 0: no memory (from the first segment) 1: Memory (from the power-down moment) F08.18 Simple PLC time unit 0: s (second) 1: min (minute) 0 ● F08.19 Setting of the first segment Ones place: Running direction options 0: forward 1: reverse Tens place: Acceleration and deceleration time options 0: acceleration and deceleration time 1 2: acceleration and deceleration time 3 1: acceleration and deceleration time 2 3:

acceleration and deceleration time 4 0 ● F08.20 Running time of the first segment 0.0~6000.0 s/min 5.0 ● F08.21 Setting of the second segment Same as F08.19 0 ● F08.22 Running time of the second segment 0.0~6000.0 s/min 5.0 ● F08.23 Setting of the third segment Same as F08.19 0 ● F08.24 Running time of the third segment 0.0~6000.0 s/min 5.0 ● F08.25 Setting of the fourth segment Same as F08.19 0 ● F08.26 Running time of the fourth segment 0.0~6000.0 s/min 5.0 ● F08.27 Setting of the fifth segment Same as F08.19 0 ● F08.28 Running time of the fifth segment 0.0~6000.0 s/min 5.0 ● F08.29 Setting of the sixth segment Same as F08.19 0 ● F08.30 Running time of the sixth segment 0.0~6000.0 s/min 5.0 ● F08.31 Setting of the seventh segment Same as F08.19 0 ● F08.32 Running time of the seventh segment 0.0~6000.0 s/min 5.0 ● F08.33 Setting of the eighth segment Same as F08.19 0 ● F08.34 Running time of the eighth segment 0.0~6000.0 s/min 5.0 ● F08.35 Setting of the nineth segment Same as F08.19 0 ● F08.36 Running time of the ninth segment 0.0~6000.0 s/min 5.0 ● F08.37 Setting of the tenth segment Same as F08.19 0 ● F08.38 Running time of the tenth 0.0~6000.0 s/min 5.0 ●