sinee — EM760 User Manual

User’s Guide for EM760 series high-performance vector inverter 78 F10.61 SCI response option 0: Reply to both read and write commands 1: Reply to write commands only 2: No reply to both read and write commands 0  F10.62 CANopen self check identification code 0~65535 0 × F11 User-selected array (for details, refer to the user's manual or the complete function table) F12 Keyboard and display function group F12.00 M.K multi-function key options 0: ESC 4: quick stop 1: forward jog 5: free stop 2: reverse jog 6: cursor movement to the left 3: forward/reverse switching 0  F12.01 Options of stop function of STOP key 0: valid only in keyboard control 1:

with all command channels valid 1  F12.02 Parameter locking 0: do not lock 1: reference input not locked 2: all locked, except for this function code 0 ● F12.03 Parameter copying 0: No operation 1: parameter upload to keyboard 2: Download parameters to inverter 0  F12.09 Load speed display coefficient 0.01~600.00 30.00 ● F12.10 UP/DOWN acceleration and deceleration rate 0.00: automatic rate 0.01 - 500.00 Hz/s 5.00  F12.11 Options of UP/DOWN offset clearing 0: do not clear 1: clear in non-running state 2: clear when UP/DOWN invalid 0  F12.12 Options of UP/DOWN power-down saving of offset 0: do not save 1: save (valid after the offset is modified) 1  F12.13 Power meter resetting 0:

do not clear 1: clear 0 ● F12.14 Restoration of default setting 0: No operation 1: restoration of factory defaults (excluding the motor parameters, inverter parameters, manufacturer parameters, running and power-on time record) 0  F12.15 Cumulative power-on time (h) 0~65535 h XXX × F12.16 Cumulative power-on time (min) 0~59 min XXX × F12.17 Cumulative running time (h) 0~65535 h XXX × F12.18 Cumulative running time (min) 0~59 min XXX × F12.19 Rated power of inverter 0.40~650.00 kW Depending ×