EPSON — ■ Monitoring and Control

40 Top Menu Sub-menu Epson Web Control Setting Availability ESC/VP21 Public Commands Command Setting Value/Response Value Settings Geometry Correction ü CORRECTMET x1 CORRECTMET? 00: Off 01: H/V-Keystone 02: Quick Corner 03: Point Correction 04: Curved Surface 05: Corner Wall H/V-Keystone ü VKEYSTONE xxx VKEYSTONE? HKEYSTONE xxx HKEYSTONE? VBALANCE xxx VBALANCE? HBALANCE xxx HBALANCE? 0-255 INIT/INC/DEC (settings only) Quick Corner ü QC x1 x2 x3 x4 x5 x6 x7 x8 (Set coordinates) x1-8: 4999- 000 Specify in the order: top left (x, y), top right (x, y), bottom right (x, y), bottom left (x, y) QC?

(Acquire coordinate settings) -4999-5000 Coordinates (x, y) for 4 points are divided into 4 lines and responded QCV x1 x2 x3 x4 x5 x6 x7 x8 (Vector settings) x1-x8: 0-99 Specify in the order: top left (x, y), top right (x, y), bottom right (x, y), bottom left (x, y) Curved Surface ü - Corner Wall ü Point Correction ü Split Screen ü SPS x1 x2 SPS? x1 01: Execute/Release Split Screen x2 00: Release Split Screen 01: Execute Split Screen x1 02: Set Screen Size x2 00: Equal 01: Larger Left 02: Larger Right x1 03: Source (Screen Left) 04: Source (Screen Right) x2 See "Switch input source". x1 05: Swap Screens x2 00: Auto 01: Screen Left 02: Screen Right x1 00:

Acquire All Current Settings (information only) x1 INIT Lock Setting Control Panel Lock ü - Lens Lock ü