Epson L-6034VW Operation Guide Touch Panel Basic Operations Print Operation Settings c Important: ❏ When using the splice detection function, make sure you use red splicing tape at least 20 mm wide. Also, make sure you use substrate with splicing tape stuck from one edge of the substrate to the other. ❏ Except when the color of the substrate surface is white, light yellow, or light blue, errors may occur and you may not be able to print. If this occurs, turn off the splice detection function, or see the following section to change the splice detection settings so that it detects the reverse printable surface.
❏ When printing over a splice, make sure the overall thickness of the point the tape overlaps or is wrinkled is 0.135 mm or less. Changing the detection side for the splice detection function A Open the top front cover and the bottom front cover on the press. B Open the safety cover for the sensor amplifier. 100 Item Explanation Operation when Substrate Joint Detected Sets the function to detect splicing tape over splices in the substrate. Since splices are not detected when Print over joints is selected, printing is performed over the splices. If splices are detected when Joint and margin (approx.
7 m) are fed and printing resumes is selected, approximately 7 m of the spliced section and margin is fed and printing restarts automatically. Auto Head Maintenance Set the operation timing when you want to perform head maintenance in addition to the head cleaning that the press performs automatically. When you select Apply in Perform Periodically (when Printing), set the operation interval. Recovery operation when paused due to high drum temperature Select the recovery operation used if the press stops due to exceeding the maximum temperature.