EPSON — Substrate Settings

Epson L-6034VW Operation Guide Touch Panel Basic Operations c Important: If Corona Treatment is set to Apply , you cannot feed the substrate in reverse to the unwinder side by inputting a negative value to Feeding Amount . Note: ❏ Displays the latest contents for the default preset on the screen. ❏ On/Off for Adjust Print Position changes according to the latest default preset content. 125 Tab Item Explanation Feed Subst Feeding Amount Set the feed amount of substrate. When you input a negative value, the substrate is fed in reverse to the un- winder side. Feed speed Set the feed speed for the substrate. Corona Treatment Set when feeding substrate while performing corona treatment.

When the printing side is a PET substrate and needs corona treatment, use this function before printing to perform corona treatment to maintain image quality and the print head quality. Do Not Apply (default) Corona treatment is not performed. Apply Corona treatment is performed. Enter a value for Feeding Amount and press Start feed to perform corona treatment while feeding the substrate. Start feed/Stop feed Press Start feed to feed the substrate for the amount set in Feeding Amount. Press Stop feed to stop feeding while feeding substrate. Config Display Units Select the unit to display the substrate width and thickness.

Substrate Length Units Select the unit to display the substrate length. Substrate Width Displays the width of the substrate loaded in the press. Used Displays the total amount of substrate fed. Press Reset on the Operation Status screen to reset the feed amount to 0.