Command List of the Alphabetical Order 1 "Priority" indicates the function is executed with priority. ESC/Label Command List Rev. C SHEET2 CW-C4000 series Command Function identifier Command name Description Classification Command code Description of parameters Definition range for ESC/Label Definition range Factory-set initial value Corresponding ZPL II command Priority 1 ^B(R GS1 Databar (HRI character attachable) ^B(R command generates GS1 DataBar as well as ^BR command. HRI character is attachable. Barcode ^B(Ra,b,c,d,e,f,g a: Field orientation a = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B: 270° rotation (clockwise) a = N/R/I/B N: Normal R:
90° rotation (clockwise) I: 180° rotation B: 270° rotation (clockwise) Low b: Type of barcode or symbol 1 ≤ b ≤12 1: GS1 DataBar 2: GS1 DataBar Truncated 3: GS1 DataBar Stacked 4: GS1 DataBar Stacked Omnidirectional 5: GS1 DataBar Limited 6: GS1 DataBar Expanded 7: UPC-A 8: UPC-E 9: EAN-13 10: EAN-8 11: UCC/EAN-128 and CC-A/CC-B 12: UCC/EAN-128 and CC-C 1 ≤ b ≤12 1: GS1 DataBar 2: GS1 DataBar Truncated 3: GS1 DataBar Stacked 4: GS1 DataBar Stacked Omnidirectional 5: GS1 DataBar Limited 6: GS1 DataBar Expanded 7: UPC-A 8: UPC-E 9: EAN-13 10: EAN-8 11: UCC/EAN-128 and CC-A/CC-B 12: UCC/EAN-128 and CC-C c: Magnification factor of barcode or symbol 1 ≤ c ≤ 99 1 ≤ c ≤ 40 d:
Height of separator d = 1/2 d = 1/2 e: Height of barcode part [dot] 1 ≤ e ≤ 32000 1 ≤ e ≤ 9600 f: Number of segments 2 ≤ f ≤ 22, even numbers only 2 ≤ f ≤ 22, even numbers only g: Set/cancel of HRI character addition g = Y/N Y: Set N: Cancel g = Y/N Y: Set N: Cancel ^B(V Set barcode printing validation function Use the ^B(V command to enable/disable the barcode printing validation function. Barcode ^B(Va a: Barcode printing validation function a = Y/N Y: Enabled N: Disabled a = Y/N Y: Enabled N: Disabled Low ^B0 Aztec Code Sets the Aztec Code symbol to the field. Barcode ^B0o,m,e,t,i,n,id o: Aztec Code field orientation o = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B:
270° rotation (clockwise) o = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B: 270° rotation (clockwise) ^B0 Low m: Aztec Code module size 1 ≤ m ≤ 99 1 ≤ m ≤ 40 e: Aztec Code extended channel interpretation (ECI) enabled/disabled e = Y/N Y: Enabled N: Disabled e = N N: Disabled t: Aztec Code mode type and data layer count t = 0 01 ≤ t ≤ 99 101 ≤ t ≤ 104 201 ≤ t ≤ 232 t = 300 t = 0 01 ≤ t ≤ 99 101 ≤ t ≤ 104 204 ≤ t ≤ 232 i: Aztec Code leader initialization symbol i = Y/N Y: Yes N: No i = N N: No n: Number of symbols for structured append with Aztec Code 1 ≤ n ≤ 26 1 ≤ n ≤ 26 id: Aztec Code message ID ASCII code within 24 characters ASCII code within 24 characters