EPSON — 1.3.4 About Saving the Graphics and Label Formats in the Printer

1.3.3 Command Syntax Format commands have command syntax rules. Control commands do not have command syntax and are effective with just a single command. Table 1.3.3 Command Syntax Rules Format commands not included between “^XA”(Begin label format) and “^XZ”(End label format) are invalid. Figure 1.3.1 Format and Field 1.3.4 About Saving the Graphics and Label Formats in the Printer With ESC/Label command, you can save graphics and label formats in the printer. The printer has a file system. Data saved in the printer is handled as files and is managed in the following way.

 The printer has a non-volatile saving device, such as Flash ROM, and a volatile saving device, such as RAM, and different drive letters are allocated for each device.  The file system does not have a hierarchy.  Files are designated as “ colon dot “. ESC/Label Command Reference Guide Rev. L Page 12 Definition Syntax rule Label format Command group that begins with “^XA”(Begin label format) and ends with “^XZ”(End label format). Field Command group that begins with “^FO”(Field position setting) and ends with “^FS”(Field end).

Field “^XA”(Begin label format) “^FO”(Field position setting) “^A”(Font designation) “^FD”(Field data setting) “^FS”(Field end) “^FO”(Field position setting) “^B4”(Barcode designation) “^FD”(Field data setting) “^FS”(Field end) “^XZ”(End label format) Field Label format