EPSON — ~H(S

~H(S [Name] Send printer operation status [Format] ~H(S a ,b [Function] Sends the printer operation status specified in Parameter a, b to the host. [Initial value] None [Response] The printer sends the printer operation status value according to the following data format.

comma comma Control code that indicates start of text (02H) “^S(S” fixed 4 characters 2-character ASCII string specified in Parameter a 1-character ASCII string specified in Parameter b ASCII character string of undefined length Control code that indicates end of text (03H) Control code that indicates carriage return (0DH) Control code that indicates line feed (0AH)  The printer does not respond if Parameter a is not 2 characters, or if it is not an ASCII character string.  A character which follows the parameter a and comma is treated as parameter b. The printer does not respond if Parameter b is not an ASCII character string.

 If an undefined identifier is specified for Parameter a or Parameter b, mode value> is set to “#NA” and sent to the host.  If Parameter a or Parameter b is omitted, the printer does not respond. ESC/Label Command Reference Guide Rev. L Page 141 Parameters Description Definition range a Printer operation status function identifier a = 2-character ASCII string For details, see Appendix B List of Printer Operation Status b Printer operation status object identifier b = 1-character ASCII string For details, see Appendix B List of Printer Operation Status