EPSON — ^MU

^MU [Name] Set units of measurement [Format] ^MU u ,i ,o [Function]  Sets the unit for specifying the rendering position and size.  The units used in Parameters for commands which specify or render positions are set based on Parameter u.  The magnification factor for the image’s vertical and horizontal directions is determined based on the ratio between Parameters i and o. The following table indicates the magnification factors that can be specified based on Parameters i and o. The combination of a rendering resolution of 200 [dpi] and a print resolution of 200 [dpi] can be used if 200 [dpi] was specified for ^S(CLR,Z.

This can be used together with specifying 2 times rendering with “^JM”. By specifying 2 times rendering with “^JM” and then specifying 3 times rendering with this command, you can specify 6 times (2 Ч 3 = 6) rendering. [Response] None [Note] If using this command, use it before defining the first field in the label format. The ^JUS command is required to save settings to the non-volatile memory of the printer unit. Please refer to the “^JU” command section for details. [Reference] Related commands: ^JM ESC/Label Command Reference Guide Rev. L Page 181 Parameters Description Definition range u Basic printer unit system u = D/I/M D: Dots I: Inches M:

Millimeters i Rendering resolution i = 150/200/300/600 [dpi] o Print resolution o = 200/300/600 [dpi] Rendering resolution Print resolution Magnification factor for the image’s vertical and horizontal directions 200 200 Equal 300 300 600 600 150 300 2 times 300 600 200 600 3 times 150 600 4 times