^SF [Name] Serialization field [Format] ^SF t ,i [Function] Sets the serialization field. If “^PQ” has been used to perform multiple-sheet printing, printing is performed proceeding in the sequence for the character string in the serialization field. If “^SF” was used, the character string specified for “^FD” or “^FV” is used as the serialization field. The format for the sequence of the character string is specified based on Parameter t. If you want to use a 3-digit decimal as the sequence, specify DDD for Parameter t. If, within a 3-digit decimal, you want to set only the first 2 digits as the sequence, specify DD% for Parameter t. The increment is set based on Parameter i.
After printing the serialized label print quantity specified for Parameter c in “^PQ”, the printer advances the sequence by the increment specified for Parameter i. [Response] None [Reference] Related commands: ^FD , ^FV [Usage example] ^XA ^FO100,100 ^FD123^SFDDD, 1^FS 1. Set increment 1 to the character string [123]. ^PQ10 2. Set 10 labels for to the total print quantity. ^XZ ESC/Label Command Reference Guide Rev. L Page 196 Parameters Description Definition range t Character string for serialization t = Character string comprised of D/H/O/A/N/% D: Decimal H: Hexadecimal O: Octal A: Letters of the alphabet N: Alphanumeric %:
Character to be ignored i Increment Numerals or letters of the alphabet