omron — CPON program instruction

CPON program instruction While asserting CPON permits continuous-path processing to occur, any of the following conditions will break a continuous path and override CPON: l No subsequent motion instruction is executed before completion of the next motion instruction. l CP system switch is disabled. (If the CP system switch is disabled, continuous-path processing never occurs, regardless of any CPON or CPOFF instructions.) l The next motion instruction is followed by an instruction that explicitly or implicitly causes motion termination (for example, BREAK, OPENI).

Related Keywords BREAK program instruction CP system switch CPOFF program instruction SELECT program instruction SELECT real-valued function eV+Language Reference Guide, v2.x, 18319-000 Rev A Page 141