FSET monitor command Using FSET With TCP The following network device may be referenced with the FSET command: TCP (Transmission Control Protocol) You can use the attributes listed in the following table when accessing this device with the FSET command. FSET Network Attributes You may define new nodes on the network using the FSET command to access the TCP device.
Examples To change the baud rate to 2400 and disable parity checks for local CPU serial line 1, type fset local.serial:1 /parity none /speed 2400 To define a new network node called SERVER2 with the IP address 192.9.200.22, type eV+Operating System Reference Guide, 2.x,18321-000 Rev A Page 103 Keyword Argument Description ON Enable recognition of CTRL+O for flushing output /SPEED 110, 300, 600, 1200, 2400, 4800, 7200, 9600, 19200, 38400 Select the indicated baud rate. For current Omron Adept boards, a baud rate of 19200 is incompatible with a baud rate of 7200 or 38400 on a pair-wise basis. The pairs are: