N/A (not specified) N/A (not specified) — X

Downloaded from https://www.everyspec.com MIL-HDBK-103BC 4.6 Electrostatic discharge sensitivity (ESD) listing. ESD classification levels, as required by MIL-PRF-38534 or MIL-PRF-38535, will be listed in the status column of section 1, part 1, of the appendix. Manufacturers are required to send these classification levels to DLA Land and Maritime-VA for all Standard Microcircuit Drawings for which they are an approved source. The ESD listing in section 1, part 1 of the appendix will be in accordance with the following:

STATUS INTERPRETATION Blank Data not submitted 0 Class 0; 1 Class 1; 0 – 1999 V 1A Class 1A; 250 V – 499 V 1B Class 1B; 500 V – 999 V 1C Class 1C; 1,000 V – 1999 V 2 Class 2; 2000 V – 3999 V 3 Class 3; ≥ 4000 V 3A Class 3A; 4000 V – 7999 V 3B Class 3B; ≥ 8000 V 5. CONFIGURATION MANAGEMENT 5.1 Configuration management of SMDs. All proposed changes to existing SMDs will be coordinated with the military activities and industry users of record for the individual documents. This coordination will be accomplished using DD Form 1693, Engineering Change Proposal (Short Form). 5.2 Record of users. Industrial users should inform DLA Land and Maritime when a system application requires use of the SMD.

When notified, DLA Land and Maritime will maintain a record of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC 5962) should contact DLA Land and Maritime-VAC, telephone (614) 692-8108. 3