N/A (no manufacturer mentioned) N/A — MIL-HDBK-304C Package Cushioning Design Handbook PDF Download

MIL-HDBK-304C Peak acceleration will not necessarily occur along all axes at the same instant of time. Therefore the peak resultant acceleration may or may not coincide with peak values of any of the components. As a result, it is necessary to analyze the data point by point along the common time base to determine resultant peak acceleration. Figure 8-8 shows a typical test record with the peaks in bold indicating the difference in time at which peak acceleration values occur. 64 D ownloaded from https://www.everyspec.com Test of Corrugated Fiberboard Container No. 4 Date 18 September 1996 Test Condition 24" Corner Drop Time 2:00 PM Package Orientation Corner 5-3-4 - Impacted By Phyllis D.

Box TIME (ms) ax (G) ay (G) az (G) Resultant ar (G) 6 7.2 6.5 3.6 11.45 8 11.9 7.6 7.1 15.78 7 15.7 9.2 10. 1 20.81 10 16.9 10.2 9.4 21.86 11 17.1 10.4 9.2 22.02 12 14.2 12.9 9.2 21.19 13 11.2 13.5 8.3 19.36 14 9.8 13.1 7.8 18.11 16 8.5 10.6 7.4 15.46 18 8.3 8.1 7.4 13.75 20 6.5 6 7.8 11.79 ______________ * Resultant (ar) = √ax² + ay² + az² * PEAKS IN BOLD FIGURE 8-8. Sample data analysis computation sheet for one instrumented container drop test. Note: Figure 8-8 lists the data and manually computes the resultant using vector addition as shown in the last column. Many computer programs are available to capture the data and perform the vector addition automatically.