Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC110 Normal Frequency Transients POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Normal PARAMETER: Normal Frequency Transients 1. Scope. 1.1 Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when subjected to normal frequency transients as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.
The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for normal aircraft electrical conditions when subjected to frequency transients within the normal limits of the applicable edition(s) of MIL-STD-704 and as noted in table TAC110-I. The utilization equipment must maintain specified performance during and after the frequency transients. The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC110-I. MIL-STD-704 limits for normal frequency transients. 3. Apparatus. The test equipment should be as follows: a.
Programmable AC power supply b. True RMS voltmeter c. Frequency counter d. Oscilloscope 61 Limit 704A 704B 704C 704D 704E 704F Normal Frequency Transients Figure 5 MIL-STD- 704A Locus of Equivalent Step Function Curves 2 and 3 ¶ 5.1.3 MIL-STD- 704B Figure 6 MIL-STD- 704C Figure 6 MIL-STD- 704D Figure 5 MIL-STD- 704E Figure 5 MIL-STD- 704F Normal Maximum Rate of Change of Frequency 250 Hz/sec N/A N/A N/A N/A N/A