U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 After all test conditions are complete, adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Conduct a performance test of the UUT according to the utilization equipment performance test procedures to confirm that the UUT has not suffered damage and is providing specified performance for normal aircraft electrical conditions. TABLE TAC110-II. Test conditions for MIL-STD-704A normal frequency transients.

63 Test Condition Time From Steady State Frequency to Frequency Transient Level milliseconds Frequency Transient Level Hz Duration at Frequency Transient Level Time From Frequency Transient Level to Steady State Frequency Overfrequency Transients A 120 msec 430 Hz ½ cycle 120 msec B 300 msec 430 Hz ½ cycle 1.2 seconds C 200 msec 450 Hz ½ cycle 200 msec D 250 msec 450 Hz ½ cycle 3 seconds Underfrequency Transients E 120 msec 370 Hz ½ cycle 120 msec F 300 msec 370 Hz ½ cycle 1.2 seconds G 200 msec 350 Hz ½ cycle 200 msec H 250 msec 350 Hz ½ cycle 3 seconds Combined Transient I 200 msec then 200 msec 350 Hz 450 Hz ½ cycle ½ cycle 200 msec 200 msec