Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC301 Abnormal Steady State Limits for Voltage and Frequency POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Abnormal PARAMETER: Abnormal Steady State Limits for Voltage and Frequency 1. Scope. 1.1 Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when provided power with voltage and frequency at the Abnormal Low Steady State (ALSS) limits and the Abnormal High Steady State (AHSS) limits as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.
The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for abnormal aircraft electrical conditions when supplied input power of voltage and frequency at the specified abnormal steady state limits of the applicable edition(s) of MIL-STD-704 and as noted in table TAC301-I. The utilization equipment must maintain specified performance for a length of time that confirms the utilization equipment can continuously operate at the abnormal steady state voltage and frequency limits and should be not less than thirty (30) minutes for each of the test conditions.
Unless otherwise specified in the utilization equipment performance specification document, the utilization equipment must demonstrate re-start at the abnormal steady state voltage and frequency limits. Unless otherwise specified in the utilization equipment performance specification document, the utilization equipment must automatically return to the performance specified for normal aircraft electrical conditions when the power returns to within normal limits. The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC301-I. MIL-STD-704 abnormal limits for steady state voltage and frequency.
77 Abnormal Limit 704A 704B 704C 704D 704E 704F Voltage ALSS 102 V 100 V 100 V 100 V 100 V 100 V Voltage AHSS 124 V 125 V 125 V 125 V 125 V 125 V Frequency ALSS 370 Hz 375 Hz 380 Hz 375 Hz 380 Hz 380 Hz Frequency AHSS 430 Hz 425 Hz 420 Hz 425 Hz 420 Hz 420 Hz