everyspec.com hydraulic manual — Chapter 8 - Flow Control Units

Downloaded from https://www.everyspec.com FM 1-509 to each other when the valve is in the OFF position. Important points to remember about hydraulic systems incorporating an open-center selector valve are-- The system is designated as an open-center system. When the selector valve is in the OFF position, the output of the system pump is returned through the selector valve to the reservoir with practically no resistance. Therefore, in an open-center system, operating pressure is present only when an actuating unit is being used. Because of this, a slight delay occurs in the response of an actuating unit in some open-center systems after the selector valve has been placed in the ON position.

Only open-center-type selector valves are used in open-center systems. No more than one actuating unit can be efficiently used at one time in an open-center system. Open-center, rotor-type selector valve. In open-center selector valves having rotor-type valving devices, two passages in the rotor interconnect the pressure and return ports with the cylinder ports. A third passage interconnects the pressure and return ports when the valve is in the OFF position.

When the selector valve is turned to the OFF position, fluid from the pump enters the selector valve pressure port and passes through the open-center passage in the rotor, through the selector valve return port, and back to the reservoir. (See Figure 8-7.) When the selector valve is moved to the ON position, its. operation is identical to that of the closed-center, rotor-type selector valve. 8-5